Leprecon LP-750 Series Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
This is a straight 6 channel chase operating in a sequence of 1-2-3-4-5-6 only. There
are 6 LEDs that make up the chase display. These LEDs will indicate the speed that
you have selected for the chase.
The chase “on/off” switch is a light-touch snap action momentary push button. At a
touch of the button the operator locks the chase function “on” or “off”. This gives the
operator quick access and a fast response time to the chase.
The chase section is grouped into blocks of 6 channels. The selector switch located on
the back of the controller can enable or disable each of these blocks. Depending on
which of the LP-700 series you have will determine how many switches you will need. If
you have 12 channels you have two blocks of 6 channels. The LP-760 has 36 channels,
which is 6 blocks of 6. The first selector switch operates block one, channels 1-6, the
second switch operates block two, 7-12, and the third operates block three, 13-18 and
so on.
BUMP
At the bottom left of the controller are the control switches for the bump buttons. This
section has two selector switches with corresponding yellow LED’s. (See figure D)
These switches allow the operator to use the bump buttons located beneath each of the
controller channels to achieve different results.
The switch marked “on/off” is the bump enable switch. The yellow LED will be glowing
when this switch is on. You may want to deactivate the bumps so accidental channel
increases will be avoided. Above the “on/off” switch is the “solo/add” switch. When
pressing a channel’s bump button, while in the “add” mode, that channel will be added at
full intensity. The bump button will “add” that channel to the existing look on stage; it will
not effect the scene setup in any other way.
When the “solo/add” switch is depressed in the “solo” position the yellow LED will glow
whenever a bump button is depressed. Also while the button is depressed the controller
will delete all of the channels that are in the “X” and “Y” scene masters, this excludes
independent and chase. This effect will last only as long as the bump button is
depressed. When the bump button is released the scene will then return to its normal
preset condition.
HINT: When the “solo” feature is activated only that channel will appear. You may
rearrange channels while the bump button is depressed and return to a new stage look.
This will give the effect of very fast scene changes with a minimum of fader work.
GRAND MASTER
The “grand master” section has 2 faders, a blackout switch and a subset of “M/I” selector
switches. The master fader, marked “M”, the independent fader, marked “I”, and the
board disable switch marked “black” are grouped together. (See figure E) The individual
“M/I” selector switches are located above their corresponding channels. These are
Seitenansicht 2
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare

White Rodgers 1F95-1277 manuali

Manuali dei proprietari e guide per l'utente per no White Rodgers 1F95-1277.
We fornisce 2 manuali pdf White Rodgers 1F95-1277 per scaricare gratuitamente in base al tipo di documento: Manuale di Installazione, Scheda delle Specifiche


White rodgers 1F95-1277 Scheda delle Specifiche (2 pagine)


Marchio: White-rodgers | Categoria: No info | Dimensione: 1.57 MB |

 

Indice





Più prodotti e manuali per no White Rodgers

Modelli Tipo di Documento
F92-0563 Scheda delle Istruzioni   White Rodgers F92-0563 Instruction Sheet, 1 pagine
1F95-0680 Scheda delle Specifiche   White Rodgers 1F95-0680 Specification Sheet (French), 2 pagine
1F98EZ-1421 Guida Utente   White Rodgers 1F98EZ-1421 User Guide (French), 20 pagine
1F85-0471 Scheda delle Specifiche   White Rodgers 1F85-0471 Specification Sheet (French), 2 pagine
3098-134 Manuale Utente    White Rodgers 3098-134 User's Manual, 4 pagine
5059-134 Pilot Relight Control Manuale di Installazione   White Rodgers 5059-134 Pilot Relight Control Installation Instructions, 4 pagine
1F95-1280 Manuale di Installazione   White Rodgers 1F95-1280 Installation and Operation Instructions (French), 16 pagine
25M01A-100 Scheda delle Specifiche   White Rodgers 25M01A-100 Specification Sheet, 2 pagine
2A37 Manuale Utente    White Rodgers 2A37 User's Manual [en] , 6 pagine
1F97-1277 Manuale di Installazione   White Rodgers 1F97-1277 Installation and Operation Instructions (French), 12 pagine
1F95-0680 Manuale di Installazione   White Rodgers 1F95-0680 Installation and Operation Instructions, 16 pagine
1F78-151 Manuale di Installazione   White Rodgers 1F78-151 Installation and Operation Instructions (French), 7 pagine
1F78-144 Manuale di Installazione   White Rodgers 1F78-144 Installation and Operation Instructions (French), 6 pagine
36C03-333 Manuale Utente   White Rodgers 36C03-333 Catalog Page, 1 pagine
152-10 Line Voltage, Locked Case Manuale Utente   White Rodgers 152-10 Line Voltage, Locked Case Catalog Page, 1 pagine
1F85RF-275 Scheda delle Specifiche White Rodgers 1F85RF-275 Specification Sheet (French) [en] , 2 pagine
1F85-0422 Manuale di Installazione   White Rodgers 1F85-0422 Installation and Operation Instructions (French), 12 pagine
50D50-843 Manuale Utente   White Rodgers 50D50-843 User's Manual, 4 pagine
80 Manuale del Proprietario   White Rodgers 80 Owner's Manual, 8 pagine
F92-1003 Manuale Utente   White Rodgers F92-1003 Catalog Page, 1 pagine